Take your total monthly bill and divide it by the average tariff you pay per unit, fixed charges included. That gives the units (kWh) you use in a month. Divide by 30 for a daily figure. A home spending ₹8,000 a month at about ₹8 a unit uses roughly 1,000 units a month, or 33 a day.
A well-sited rooftop plant in North India yields about 4 units per kWp per day over the year, after losses. Divide the daily need by that yield to find the size that would cover the whole bill.
Real yield depends on tilt, shading, dust and the inverter. The site survey replaces this assumption with measured values.
The smallest of the four results sets the plant size.
Panel count follows from the module rating. With 620 Wp modules, 5 kWp is eight panels (4.96 kWp) or nine (5.58 kWp). Which one is right depends on the inverter's input range and how the strings are arranged.
We draw a single line diagram, size the cables and protection, plan earthing, and check the mounting structure against wind load on your roof. Only then do we freeze the bill of materials.